  Modified 07-OCT-2010     Type PROBLEM     Status PUBLISHED  

Applies to:

Hyperion Financial Data Quality Management - Version: 11.1.1.2.00 to 11.1.1.2.00 - Release: 11.1 to 11.1
Information in this document applies to any platform.

Symptoms

An error is being returned when you try to export using the HE-6x-G4D adapter.  A review of the error log shows the below two statements:

** Begin Oracle Hyperion FDM Enterprise Adapter Runtime Error Log Entry [2009-04-14-09:26:06] **
------------------------------------------------------------- 
ERROR: 
Code..............453 
Description.......Can't find DLL entry point _EntSetSourceName@8 in hacces32.dll 
Procedure.........clsHPDataManipulation.fDBLoad 
Component.........upsHE6xG4D 
Version...........100 
Thread............2728 

** Begin FDM Runtime Error Log Entry [2009-04-14-09:26:15] ** 
------------------------------------------------------------- 
ERROR: 
Code............................................. 4117 
Description...................................... Stream Failed, Invalid file path provided! 
\\vmh-wpaffhau2\fdmdata\vm0wp11112\BlankAppSQL\Data\3.ua2 
Procedure........................................ clsAppServer.fFileGetStream

Cause

The adapter is trying to use the 'Enable Drillback' function in a version of Hyperion Enterprise that is not supported. 

Solution

Ensure in the Adapters Integration Settings that the 'Enable Drillback' option is not selected for an inappropriate version of Hyperion Enterprise.  Consult the ReadMe.PDF documentation for further details on which versions of Hyperion Enterprise support DrillBack into FDM.