When Exporting in FDM with the HE-6x-G4D Adapter the Error: "Stream Failed, Invalid file path provided!" is Returned | |||||
|
|||||
Modified 07-OCT-2010 Type PROBLEM Status PUBLISHED |
Applies to:
Hyperion Financial Data Quality Management - Version: 11.1.1.2.00 to 11.1.1.2.00 - Release: 11.1 to 11.1Information in this document applies to any platform.
Symptoms
An error is being returned when you try to export using the HE-6x-G4D adapter. A review of the error log shows the below two statements:
** Begin Oracle Hyperion FDM Enterprise Adapter Runtime Error Log Entry [2009-04-14-09:26:06] **
-------------------------------------------------------------
ERROR:
Code..............453
Description.......Can't find DLL entry point _EntSetSourceName@8 in hacces32.dll
Procedure.........clsHPDataManipulation.fDBLoad
Component.........upsHE6xG4D
Version...........100
Thread............2728
** Begin FDM Runtime Error Log Entry [2009-04-14-09:26:15] **
-------------------------------------------------------------
ERROR:
Code............................................. 4117
Description...................................... Stream Failed, Invalid file path provided!
\\vmh-wpaffhau2\fdmdata\vm0wp11112\BlankAppSQL\Data\3.ua2
Procedure........................................ clsAppServer.fFileGetStream
Cause
The adapter is trying to use the 'Enable Drillback' function in a version of Hyperion Enterprise that is not supported.Solution
Ensure in the Adapters Integration Settings that the 'Enable Drillback' option is not selected for an inappropriate version of Hyperion Enterprise. Consult the ReadMe.PDF documentation for further details on which versions of Hyperion Enterprise support DrillBack into FDM.