FDM Schema Update Error "91 - Object Variable with Block Variable Not Set" [ID 603737.1] | |||||
|
|||||
Modified 19-APR-2010 Type PROBLEM |
Applies to:
Hyperion Financial Data Quality Management - Version: 8.3.1.0.00 to 11.1.1.3.00 - Release: 8.3 to 11.1Information in this document applies to any platform.
Symptoms
Receiving "Schema Update Failed" message when attmpeting to run schema update utility on an FDM Application. Customer is receiving "Schema Update Failed" error when attempting to run the schema update utility on an FDM Application to upgrade the application to a newer schema level.Cause
Microsoft Excel was not installed on FDM Application Server(s) Microsoft Excel is required for Schema Update to run successfully and is noted in the FDM Administration Guide.
Also it is noted that there should be no add-ins enabled in Excel. This includes Smartview and Retrieve for HFM/Essbase.
GKontos